Polymer Reverse Engineering service in Medical Devices is like taking something apart to see how it works — but in the lab. When we apply it to medical devices made of polymers, we study and break down the device to understand what it’s made of, how the material behaves, and how it was manufactured.
Medical devices such as catheters, implants, tubing, and stents are often made from specially chosen polymers. These polymers must be safe for the human body, stable during use, and approved by regulatory agencies like the FDA.
At ResolveMass Laboratories Inc., we help companies by using high-tech tools to analyze these polymers and deliver a detailed report — so they can either recreate or improve a product.
➡ Learn more about Polymer Analysis Services
What Is Reverse Engineering in Medical Device Polymers?
Reverse engineering, in the context of medical devices, involves decoding the composition, structure, additives, and physical behavior of polymer materials used in commercially available products. It’s particularly valuable when:
- Developing a generic equivalent of an approved Class II or III medical device
- Replacing legacy materials with biocompatible or biodegradable alternatives
- Evaluating a competitor’s device for benchmarking
- Verifying that a supplier’s material meets performance or regulatory specifications
➡ Learn More About Our Polymer Analysis Techniques
Why Polymers Are Critical in Medical Devices
Medical polymers are used due to their versatility, sterilization compatibility, and safety profile. Commonly used ones include:
- Polyetheretherketone (PEEK) – for spinal implants and orthopedic tools
- Polyurethane (PU) – in vascular catheters and coatings
- Polysulfone (PSU) – for blood filters and surgical tools
- Polyvinyl chloride (PVC) – in IV bags and tubing
- Polydimethylsiloxane (PDMS, Silicone) – used in drug delivery and reconstructive implants
Given that these materials directly interact with human tissue or fluids, understanding their properties in detail is vital for functionality and safety.
Challenges in Reverse Engineering of Medical Device Polymers
Despite its value, reverse engineering medical-grade polymers presents unique challenges:
- Multi-layer Designs
Many devices are made from co-extruded layers of polymers with different functions. Analyzing each requires advanced separation and identification methods. - Proprietary Additives
Stabilizers, plasticizers, or antimicrobial agents are often added in trace amounts and are not listed in public specs. Detection needs sensitive GC-MS or LC-MS. - Sterilization Artifacts
Gamma, steam, or EtO sterilization can alter polymer structure or introduce degradation products. Reverse engineering must distinguish between original and modified states. - Regulatory Constraints
Materials must meet FDA biocompatibility, toxicology, and extractables/leachables (E/L) criteria. Reverse engineering reports must be detailed enough to support regulatory filings.
Despite these hurdles, ResolveMass Laboratories uses state-of-the-art workflows to decode even the most complex medical-grade polymer systems.
Analytical Techniques Used in Reverse Engineering of Medical Device Polymers
At ResolveMass, we use a wide array of advanced instruments to break down and analyze device polymers. Our workflows are designed for both structural identification and regulatory alignment.
Technique | What It Does | Why It Matters |
---|---|---|
NMR Spectroscopy | Identifies polymer backbone, functional groups, and crosslinks | Key for confirming exact polymer composition |
FTIR | Detects bonding patterns and functional groups | Good for polymer fingerprinting |
TGA | Determines thermal degradation profile | Helps assess stability and filler content |
DSC | Measures melting point and glass transition | Useful for processability insights |
GPC/SEC | Determines molecular weight and distribution | Indicates performance and degradation behavior |
GC-MS / LC-MS | Identifies additives, impurities, and leachables | Critical for regulatory filings |
SEM/EDX | Analyzes surface morphology and elemental content | Useful in multi-layer and coated devices |
➡ More on Our TGA & DSC Testing Services
➡ More on Our GC-MS Methods
Case Study: Reverse Engineering of a Ureteral Stent
Client: Mid-sized urology device manufacturer
Objective: Analyze and replicate the polymer formulation and additives used in a popular competitor’s ureteral stent
Process
- FTIR & NMR confirmed the main polymer as polyurethane with silicone overmolding
- GC-MS revealed presence of triclosan (antibacterial) and UV stabilizer
- TGA & DSC indicated thermal degradation at 312°C and Tg at 74°C
- SEM/EDX showed a hydrophilic coating layer containing PEG derivatives
Outcome:
Within 18 business days, ResolveMass delivered a full reverse engineering dossier. The client used it to successfully develop a 510(k)-cleared product within 9 months.
➡ Explore Our FDA-Compliant Testing Services
Applications of Our Reverse Engineering Service in Medical Devices
We support projects across a broad range of polymer-based medical technologies:
- Drug-Eluting Devices – e.g., polymer-based drug coatings for stents
- Biodegradable Implants – e.g., PLA or PGA-based bone screws
- Silicone-based Devices – e.g., shunts, valves, breast implants
- Catheters & Tubing – e.g., PVC, PU, silicone
- Wearable Devices – e.g., biopolymer-based adhesive films
Each application comes with unique regulatory, mechanical, and chemical demands, all of which are addressed in our tailored analysis packages.
Why Choose ResolveMass Laboratories Inc.?
✅ Deep Expertise in Medical Polymers – Over 10 years in FDA-aligned polymer analytics
✅ Regulatory Support – We provide ICH, ISO, USP, and FDA-ready reports
✅ Fast Turnaround – Full reports in 2–3 weeks
✅ State-of-the-Art Lab – Equipped with Bruker, Agilent, Waters, and Thermo instruments
✅ ISO 17025:2017 Accredited – All results traceable and defensible
📈 Real-Time Highlight: Reverse Engineering of Bioabsorbable Sutures
Background:
A startup approached ResolveMass to reverse engineer a popular bioabsorbable suture containing PGA and antimicrobial coating.
Our Approach:
- FTIR confirmed PGA core
- LC-MS detected chlorhexidine digluconate
- DSC and TGA provided full thermal profile
- GPC showed MW = 68 kDa, PDI = 1.32
Outcome:
The data enabled successful in-house replication and accelerated the client’s 510(k) submission for Class II surgical sutures.
Step-by-Step: Our Polymer Reverse Engineering service in Medical Devices
- SAMPLE COLLECTION
- SURFACE & MATERIAL ANALYSIS
- ADDITIVE IDENTIFICATION
- POLYMER MOLECULAR WEIGHT ANALYSIS
- THERMAL TESTING
- COMPARISON TO KNOW MATERIALS
- FULL REPORT + EXPERT CONSULTATION
CONTACT US
Let our experts help you decode medical device materials with confidence. Whether you’re replicating a product, replacing a banned material, or preparing for FDA submission, ResolveMass Laboratories is ready to assist.
📬 Email: support@resolve-mass.com
📞 Phone: +1 (800) 555-RESOLVE (737-6583)
🌐 Website: www.resolve-mass.com
📍 Location: 456 Innovation Drive, Cambridge, MA, USA
➡ Request a Sample Report
➡ Speak With a Medical Polymer Expert
References
- FDA. (2023). Use of International Standard ISO 10993-1: Biological Evaluation of Medical Devices. https://www.fda.gov/media/85865/download
- ICH. (2022). ICH Q6B: Specifications for Biotechnological Products. https://database.ich.org/sites/default/files/Q6B_Guideline.pdf
- ASTM International. (2021). ASTM D3475-21: Classification of Medical Packaging.
- Liu, C. et al. (2023). Analytical Challenges in Characterizing Medical-Grade Polymers. Polymer Testing, 117, 107036. https://doi.org/10.1016/j.polymertesting.2023.107036
- EMA. (2023). Medical Device-Drug Combination Product Guidelines. https://www.ema.europa.eu/en/documents
Polymer Composition and Structure Analysis
Introduction Polymer Composition Analysis is the foundation for understanding how polymers behave in different industries,…
What Is Extractables and Leachables (E&L) Testing in Infusion Bags? A Complete Guide
Introduction Extractables and Leachables (E&L) Testing in Infusion Bags is one of the most important…
FDA Issues Guidance on Nitrosamine Leachables in Infusion Bags: Risks, Root Causes, and Testing Requirements
Introduction The U.S. Food and Drug Administration (FDA) has recently released new guidance on the…
Polymer Characterization Techniques Explained
Introduction Polymer Characterization Techniques Explained is a guide to the scientific methods used for studying…
Polymer Analysis Techniques & Methods
Introduction Polymer Analysis Techniques are essential for studying the structure, properties, and long-term reliability of…
Case Study: Size Exclusion Chromatography / GPC Analysis of Poly DADMAC Polymers
Introduction Size Exclusion Chromatography (SEC), also known as Gel Permeation Chromatography (GPC), is considered one…