Ubenimex-d7 HCl ( Bestatin-d7 HCl)

$1,000.00

  • Pack size: 10 mg, For larger quantity, please enquire.
  • Availability: Lead time 4-6 weeks
  • Catalogue number: RM-D-666
  • Synonyms: Bestatin hydrochloride, Ubenimex hydrochloride, (-)-Bestatin hydrochloride
  • Price Match Policy: We match verified competitor quote prices.
SKU: RM-D-666 Category:

Ubenimex-d7 HCl (Bestatin-d7 HCl)

Ubenimex-d7 HCl, also known as Bestatin-d7 HCl, is a stable isotope-labeled analog of Ubenimex (Bestatin) in which seven hydrogen atoms are replaced with deuterium (²H). This isotopic modification preserves the compound’s chemical and chromatographic behavior while providing a distinct mass shift, making it an ideal stable isotope-labeled internal standard (SIL-IS) for quantitative LC-MS/MS, LC-HRMS, GC-MS, and other mass spectrometry-based analytical methods. The +7 Da mass difference allows clear differentiation between the labeled internal standard and the unlabeled analyte without affecting extraction efficiency, chromatographic retention, or ionization characteristics.

At ResolveMass Laboratories Inc., Ubenimex-d7 HCl is supplied exclusively for research and analytical applications. It is intended to support pharmaceutical, bioanalytical, pharmacokinetic, toxicokinetic, metabolism, and clinical research laboratories requiring accurate quantification of Ubenimex in complex biological matrices.

Chemical Properties of Ubenimex-d7 HCl

Property Description
Product Name Ubenimex-d7 HCl (Bestatin-d7 HCl)
Synonyms Bestatin-d7 Hydrochloride, Ubenimex-d7 Hydrochloride
Molecular Formula C16H24D7N3O4·HCl
Molecular Weight Approximately 383.9 g/mol (varies slightly depending on isotopic enrichment)
Isotopic Label 7 Deuterium (²H, d7)
Appearance White to off-white crystalline powder
Chemical Class Stable isotope-labeled aminopeptidase inhibitor
CAS Number Product-specific (may vary by supplier)
Purity Typically ≥98% (HPLC)
Isotopic Purity Typically ≥98 atom % D
Solubility Soluble in water, methanol, and DMSO; limited solubility in less polar organic solvents
Physical State Solid
Retention Behavior Nearly identical chromatographic retention as unlabeled Ubenimex

Importance of Stable Isotope-Labeled Internal Standards

Quantitative bioanalysis requires exceptional accuracy, reproducibility, and robustness. Stable isotope-labeled compounds such as Ubenimex-d7 HCl are widely regarded as the gold standard for internal standardization because they compensate for variations introduced during sample preparation, extraction recovery, chromatographic separation, and ionization in the mass spectrometer.

Unlike structural analogs, Ubenimex-d7 HCl co-elutes with the native analyte while remaining distinguishable by its unique molecular mass. This enables analysts to minimize matrix effects, improve analytical precision, and generate highly reproducible quantitative data across multiple analytical batches. Regulatory agencies generally recommend stable isotope-labeled internal standards for LC-MS/MS bioanalytical assays because they provide superior method performance and data reliability.

Applications

Ubenimex-d7 HCl is extensively used in pharmaceutical research and analytical laboratories for numerous applications, including:

  • LC-MS/MS quantitative bioanalysis
  • Pharmacokinetic (PK) studies
  • Toxicokinetic (TK) studies
  • Drug metabolism investigations
  • Therapeutic drug monitoring (research use)
  • Bioequivalence studies
  • Method development and validation
  • Clinical research sample analysis
  • Stability studies
  • Reference standard development
  • High-resolution mass spectrometry method optimization
  • Analytical quality control

Because the labeled compound behaves almost identically to native Ubenimex throughout sample preparation and chromatographic separation, it effectively corrects for experimental variability and improves assay reproducibility.

Advantages of Ubenimex-d7 HCl

Researchers increasingly prefer Ubenimex-d7 HCl over non-isotopic internal standards due to several analytical advantages:

Excellent Matrix Effect Compensation

Biological samples such as plasma, serum, urine, and tissue homogenates contain endogenous components that may suppress or enhance ionization. Since Ubenimex-d7 HCl closely mimics the analyte, it experiences identical matrix effects, allowing accurate compensation during quantitative analysis.

Improved Quantitative Accuracy

The deuterium label provides a distinct mass shift while preserving nearly identical chemical properties. This enables precise correction for recovery losses, extraction variability, and instrumental fluctuations.

Enhanced Method Precision

Stable isotope-labeled internal standards significantly reduce assay variability, resulting in lower relative standard deviations (RSDs) and improved reproducibility between analytical runs.

High Sensitivity

The unique isotopic mass allows clear discrimination from endogenous compounds and background interferences, supporting sensitive quantitative analysis at low concentration levels.

Regulatory Acceptance

Stable isotope-labeled internal standards are widely recognized as the preferred approach for quantitative LC-MS/MS bioanalysis during method validation and regulated pharmaceutical studies.

Role in LC-MS/MS Bioanalysis

Modern LC-MS/MS workflows require highly reliable internal standards to achieve accurate quantification across diverse biological matrices. Ubenimex-d7 HCl fulfills this requirement by exhibiting nearly identical chromatographic retention time, extraction behavior, and ionization efficiency compared to unlabeled Ubenimex.

During multiple reaction monitoring (MRM) analysis, the native analyte and the deuterated internal standard produce separate precursor ions because of the +7 Da isotopic mass shift. This allows simultaneous monitoring without analytical interference while maintaining excellent quantitative performance.

The use of Ubenimex-d7 HCl also improves assay robustness during:

  • Protein precipitation
  • Liquid-liquid extraction
  • Solid-phase extraction
  • Sample evaporation
  • Reconstitution
  • Instrumental analysis

Pharmaceutical Research Applications

Ubenimex has attracted significant scientific interest because of its activity as an aminopeptidase inhibitor, particularly against aminopeptidase N (CD13/APN), aminopeptidase B, and leukotriene A4 hydrolase. These biological targets have been investigated in oncology, immunology, inflammation, and other therapeutic research areas. Consequently, Ubenimex-d7 HCl serves as a valuable analytical reference material for researchers studying the pharmacokinetics, metabolism, and bioanalysis of Ubenimex and related compounds.

Quality Considerations

High-quality isotope-labeled reference standards are essential for reliable quantitative analysis. Researchers typically select Ubenimex-d7 HCl based on several critical quality attributes:

  • High chemical purity
  • High isotopic enrichment
  • Confirmed identity by LC-MS or HRMS
  • Consistent batch-to-batch performance
  • Excellent stability under recommended storage conditions
  • Comprehensive analytical documentation

Reliable reference materials contribute directly to method validation, assay robustness, and long-term analytical reproducibility.

Suitable Research Areas

Ubenimex-d7 HCl supports a wide range of research disciplines, including:

  • Pharmaceutical development
  • Drug discovery
  • Clinical pharmacology
  • Bioanalytical method development
  • Translational medicine
  • Metabolite identification
  • Pharmacokinetic profiling
  • Toxicology research
  • CRO and CDMO analytical services
  • Academic research laboratories

Its versatility makes it an essential analytical tool for organizations developing sensitive and regulatory-compliant mass spectrometry methods.

Why Choose ResolveMass Laboratories Inc.?

ResolveMass Laboratories Inc. specializes in supplying high-quality stable isotope-labeled reference standards that support advanced pharmaceutical and bioanalytical research. Our products are designed to meet the demanding requirements of LC-MS/MS laboratories involved in drug development, pharmacokinetic studies, analytical method validation, and quantitative bioanalysis.

By providing reliable isotope-labeled compounds with rigorous quality standards, ResolveMass helps researchers achieve greater analytical accuracy, improved reproducibility, and confidence in quantitative mass spectrometry workflows.

 

Learn more about Deuterated Chemicals through,

PubChem CID

Reviews

There are no reviews yet.

Be the first to review “Ubenimex-d7 HCl ( Bestatin-d7 HCl)”

Your email address will not be published. Required fields are marked *

Scroll to Top
Review Your Cart
0
Add Coupon Code
Subtotal